Schober abrasion tester experimental operation
The Schober abrasion tester uses a rotational wear test method to test the wear resistance of automotive interior materials, especially interior leather coatings.
Gellowen Science is the supplier of the old brand standard equipments providing products covering multi-industries.Gellowen Science enjoys high-level world-renowned reputation and has built strategic cooperation relationship with many multinational corporation.Meanwhile, our company is also engaged in developing for testing equipments of many fields, especially we provide customized equipments for our customers. We have talented people in researching, developing, designing and producing software and hardware to provide testing equipments with high quality, stable testing procedures and highly intelligent.The testing equipments we supplied cover production, teaching, researching, quality inspection etc. and the products are according with standards in differrent regions and countries including EN, ISO, BS.
Applicable standards:
DIN 53863part2 "Abrasion test on textile surfaces (rotational wear test)", GME Standard60345, GMW Standard3283, VW/Audi PV3908
Test principle:
The circular specimen is installed on the rotating test head. The specimen is rubbed against the friction object (sandpaper) in clockwise and counterclockwise directions at a certain speed, pressure, and number of rotations by using a rotational wear method. The friction object maintains linear contact with the sample, so it can produce a friction effect in the tangent direction. Change the rotation direction every 100 frictions (settable), and evaluate the test results by mass loss and hole generation.
Technical Parameters:
1. Number of revs: 75l/min;
2. Taperangle: 166°;
3. Declination of mounting head support: 7°;
4. Specimen size: 100cm2;
5. Test area: 50cm2;
6. Arc height measuring device, 0 - 10mm adjustable;
7. Loads on specimen: 0.5 - 25N adjustable;
8. Loading weight: 50g, 100g, 250g, 500g, 1000g, 1500g;
9. External dimension: 325×565×560mm;
10. Weight: 35kg;
11. Power supply: 115/240V, 50/60Hz;
12. Power consumption: 130W.
Experimental operation:
1. Use the accessories configured by the instrument to install the sample that has been treated with temperature and humidity on the sample fixture to form a rotating test head;
2. Use the arch height test device to adjust the protruding height of the test head according to relevant standards or other requirements, generally 5 to 8 mm;
3. Install the test head with the sample on the test head mounting plate on the instrument workbench, and install and tighten the test head through the cooperation of the positioning pin on the mounting plate and the positioning hole under the test head;
4. Use the positioning Install the friction sandpaper on the lower surface of the pressure plate with the friction fixture on the pressure plate of the instrument, and lock the fixture to ensure that the sandpaper is clamped and installed flat;
5. Manually pull outward the pressure plate lifting lock on the right side of the pressure plate, lower the pressure plate, and make the sandpaper contact with the surface of the sample on the test head;
6. Install the corresponding weight on the weight shaft above the pressure plate (equipped with one standard weight of 1500, 1000, 500, 250, 100, and 50g each) to apply a certain pressure to the sample friction. Select the pressure value to be applied according to the weight of the sample per unit area.