T114 Automotive Interior Material Atomization Tester Operation Steps
T114 Automotive Interior Material Atomization Tester is suitable for high-temperature volatile atomization tests of automotive interior materials such as dashboards, knobs, seat cushions, floor leather, plastic particles, carpets, leather, adhesive products, ceiling materials, etc.
Gellowen Science is the supplier of the old brand standard equipment, offering a comprehensive range of products across multiple industries. With a world-renowned reputation, Gellowen Science has established strategic partnerships with numerous multinational corporations. Our company is also actively involved in developing testing equipment for various fields, particularly focusing on providing customized solutions for our customers. We boast a talented team in research, development, design, and production of software and hardware, ensuring our testing equipment offers high quality, stable testing procedures, and advanced intelligence. Our testing equipment caters to production, education, research, quality inspection, and more, adhering to standards from different regions and countries, including EN, ISO, and BS.
Measuring methods:
Weight method:
DIN 75201-B, ISO 17071, DIN EN 14288-B, ISO 6452-B, SAE J1756, PV 3015, GME 60326-A, GMW 3235-B, TSM05036-B, D45 1727
Gloss method/reflection method:
DIN 75201-A, DIN EN 14288-A, ISO 6452-A, PV 3015, PV 3920, TSM05036-B, D45 1727
Haze method:
DIN 75201-A, HES D6508-95, MS 300-54
Operation steps:
1. First: prepare the accessories and test samples
2. Place the prepared sample in the fogging cup
3. Prepare a piece of aluminum foil, put it in the balance to weigh, and record the value
4. Place the aluminum foil and glass plate on the top of the fogging cup
5. Set the cycle parameters of the low-temperature control box
6. Set the host temperature and time parameters
7. Start the instrument, reach the timing time, take out the aluminum foil from the workstation, put it in the balance again to weigh, and record the value
8. After the test, measure the fogging value or weight of the glass plate or aluminum foil, and compare it with the data before condensation, so as to obtain the fogging and volatilization characteristics of the sample.