The building material smoke density tester main parameters

  The building material smoke density tester is suitable for measuring the static smoke production of building materials,their products,and other materials during combustion.It is mainly used for evaluating the flame retardant grade B1 of insulation materials such as extruded polystyrene boards and polystyrene boards,and is also suitable for evaluating the smoke density grade of flame retardant decorative fabrics.


  Compliant with standards:


  GB/T 8627-2007"Test Method for Smoke Density of Combustion or Decomposition of Building Materials"


  GB/T 8624"Classification and Evaluation of Burning Performance of Building Materials and Products"


  ASTM D2843

20151202101743_56365_副本.jpg


  Main parameters:


  1.Measurement range of smoke density value:0-100%,capable of subdividing smoke density with 0.1%variation;


  2.Calibration filter specifications:approximately 1 piece each for 25%,50%,and 75%;


  3.Smoke density measurement accuracy:±3%;


  4.Combustion gas source:>85%propane gas(customer provided);


  5.Burner working pressure:276KPa(adjustable);


  6.The burner angle is fixed,and the inner diameter of the Bunsen burner nozzle is 0.13mm,with a working inclination angle of 45°;


  7.Burning time:4 minutes;


  8.Power supply:AC220V±10%,50Hz,100W;


  9.Instrument size:900mm x 450mm x 910mm.